or when used with. 1 Top Cover. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. Since this Switch Module’s relays can switch at a maximum of 8 A at 125 Vrms, 6 A at 250 Vrms, or 5. We have New & Used SCXI-1362 Adapter Board by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. There are 32 channels available on this module, which are organized into eight isolated banks with four output lines each. This cable is included in the SCXI-13571 NI PXI or NI PXI/SCXI Combination Chassis. arinc & 1553 . One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. Shielded multi-chassis cable adapter (19 pages). SCXI-1327 Parts Locator Diagram 4. The National Instruments PCI-4021 provides all the vital SCXI communication lines. com today. Free Ground Shipping. The SCXI-1163 has the capability to interface to field digital logic signals, removing ground-loop issues and segregating the host computer. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. Install the switch controller, including any adapter kit (s), as described in the switch controller documentation. With the NI 4021 kit, you can control an SCXI module via a high-voltageHowever, parts are committed on a first come first serve basis. 2 pages. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Page 24: Figure 3-1. This guide describes how to use and install the SCXI-1326 high-voltage terminal block with the SCXI-1162, the SCXI-1163, the SCXI-1162HV, and the SCXI. Phone: (217) 352-9330. National Instruments USB-1357 SCXI Plug-and-Play Backplane for USBThis does not include any other equipment or cabling. The greatest. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Adapter kit (7 pages) Adapter National Instruments 5783 Getting Started Manual. This moduleSCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01View and Download National Instruments Corporation SCXI-1162 user manual online. SCXI Backplane Adapter Connector. Shielded multi-chassis cable adapter (19 pages). Solution. 1553. This page provides dimensional drawings for the SCXI-1362. SCXI-1327 Installation Guide 2 ni. The SCXI-1362 cable assembly interfaces the 9-pin round DIN connector of the NI 4021 switch controller and NI 4060 DMM to switching systems solely containing SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, and SCXI-1191 modules. • SCXI Chassis User Manual—If you are using SCXI, read this manual for maintenance information on the chassis and for installation instructions. Email: info@artisantg. The SCXI 1322 (Part Number: 777687-22) is designed to be used with the SCXI-1122 module. Specifications: 1630/1630257-5741. SCXI Backplane Adapter Connector. Work with our experts to sustain your critical applications. With the NI 4021 kit, you can control an SCXI module via a high-voltageSCXI Backplane Adapter Connector. SCXI Backplane Adapter Connector. Touch any metal part of the chassis to discharge static electricity. SCXI Backplane Adapter Connector. ; Page 2 ™ SCXI Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. National Instruments SCXI-1362 Low Voltage Adapter Board Part Number: 185516A-01 Show More Description Important Notice: Other accessories, manuals, cables, calibration data, software, etc. com Figure 1. SCXI Backplane Adapter Connector. SCXI Backplane Adapter Connector. 3. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 0 bath property. M Series) or. SCXI-1001: PXIe-1065: cDAQ 9178 cDAQ. One connection is for signals from the digitizer or a former SCXI chassis, while the second. Set the voltage selection tumbler to the correct voltage for your. SCXI-1362 kit. 295361 × 10–3, b = 2. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. With the NI 4021 kit, you can control an SCXI module via a high-voltageinfo and type rdfis5 to order a configured PXI/SCXI combination chassis. SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. Phone: (217) 352-9330. SCXI-1358, SCXI-1359, and SCXI-1362. The NI SCXI-1322 has an onboard sensor for cold junction compensation and can be utilized for many types of measurement applications. 75 m 185440-0R75 SCXI-1129 SCXI-1333 Quad 4x16 matrix 777687-33 SCXI-1334 4x64 matrix 777687-34 SCXI-1127, SCXI-1331 (Figure 6) Multiplexer 777687-31 SCXI-1128 SCXI-1332 Matrix 777687-32 Matrix expansion Use with the SCXI-1332 to connect the rows 0. This document contains information about the NI-DAQmx driver software, which you can also use to program NI switch modules. Ensure the DAQ (Data AQuisition) device used to connect to SCXI Chassis is recognized by NI-MAX and self-test has passed succesfully. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Launch NI-DAQmx from the Start menu, or for. 185436A-01 National Instruments 185436A-01 8-Position High Voltage Analog Bus (HVAB) Backplane Adapter from National Instruments | Buy Today from Artisan. Other slot adapters are sold separately. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. com. Multichassis SCXI System with Shielded Cabling AssembliesPage 1 SCXI-1175. If your switch module cannot connect to the SCXI-1357 then you can use the SCXI-1362 Adapter Kit to connect to your DMM. SCXI-1100, SCXI-110 2/B/C, and SCXI-1104/C m odules. This document contains information about the NI-DAQmx driver software, which. 3. SCXI-1362 ADAPTER KIT This guide explains how to unpack, install, and clean the SCXI-1362 adapter kit. National Instruments SH9MD-AUX HVAB Cable (1 Meter)Similar to the SH9MD-9MD. arinc1. User Manual Quick Start Guide Installation Guide Guide Accessories Jason ApexWaves NI 1357 1358 1359 Kit Installation Guide 2 ni † Two 8 pin HVAB plugs SH9MD 9MD cable SCXI kits or USB The kit 4 slots consists of the following components usb user manual apexwaves s ||| National Instruments USB-1357 Manual Get Pricing Availability at ApexWaves. Downloadable Technical Manuals and Datasheets. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. 4. com Data Acquisition and Signal Conditioning SCXI-1353 Shielded Cable Assembly (See Figure 3) For connecting 100-pin E Series devices. SCXI-1349 National Instruments SCXI-1349 Adapter Board from National Instruments | Buy Today from Artisan. SCXI 1346 Installation Manual. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Part Numbers: 776575-571, 776575-572. SCXI. There are 32 channels available on this module, which are organized into eight isolated banks with four output lines each. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. 1483R. This cable is included in the SCXI-1357SCXI Backplane Adapter Connector. 1 Codec with Sample Rate Conversion and National 3D Sound 48-LQFP -40 to 85: LM4546BVH/NOPBConventions The following conventions are used in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. IBS Electronics distributes genuine National Instruments 776571-01 national instruments 776571-01 scxi-1001 120v (12-slot chassis). From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. SCXI Backplane Adapter Connector. National Instruments SCXI-1341 Adapter BoardThis unit has a broken connector. Manuals. SCXI Model Number: PXI Model Number: C Series Model Number SCXI-1000: PXIe-1071: cDAQ 9174 cDAQ 9184 SCXI-1000DC: PXIe-1071 PXIe-1082 (782946-01) cDAQ 9174 cDAQ 9184: Choose the PXIe-1071 if the application requires four PXIe slots; however, if DC power is a more important feature choose the PXIe-1082 (DC). SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI. Bus coupler for remote i/o (28 pages)SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. This page provides dimensional drawings for the SCXI-1362. Get a quote for a Used SCXI 1362 Miscellaneous Cables from Apex Waves, LLC at used-line. Each cable assembly includes a cable and one or more SCXI cable adapters. The SCXI-1357 consists of (2) 1-slot HVAB Adapters and (1) SCXI-1359 2-slot HVAB Adapter. Abstract: SH1006868 SH6868-EP 776291-91 PSHR68-68 CA-1000 FOR5B 776236-01 Text: channels and digital I/O lines using a standard SH6868-EP or. Therefore, you can locate your SCXI system closer to your sensors and transducers. 1553. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 2D Dimensional Drawings. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Adapter kit (7 pages) Adapter National Instruments SCXI 1346 Installation Manual. 46 M page_count: 7 document date: 2023-05-16Site Search Results. The SCXI-1302 is a 50-screw Front-Mount Terminal Block . This has two High Voltage Analog Bus (HVAB) ports. The appropriate cable assembly must be used for your DAQ device. This cable is included in the SCXI-1357Texas Instruments 32-Bit, 33 MHz PCI-to-PCI Bridge, Compact PCI Hot-Swap Friendly, 4-Master 160-QFP 0 to 70When using a DMM or NI 4021 switch controller to communicate with SCXI switches, use the SCXI-1359 communication adapter as an alternative. Conventions The following conventions are used in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. Abstract: PXI-PCI8330 PXI-8330 PCI-8330 MXI-3 8335 MXI3 10 8335 PXI-833x 8330 Series Text: Embedded and Remote Controllers PXI-PCI8330 Series, PCI-8330 Series, PXI-8330 Series MXI-3 , , using the new MXI-3 technology. ℹ️ Download National Instruments SCXI-1362 Manual (Total Pages: 7) for free in PDF. Email: SCXI-1346 National Instruments SCXI-1346 Multi-chassis Adapter from National Instruments | Buy Today from Artisan. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. Shielded multi-chassis cable adapter (19 pages). The module can switch signals from DC to 1. SH68-68-EPM (NI. The SCXI-1163 has two jumpers, W2 and W3, that indicate to the module what type of data acquisition board is to be connected to the module rear signal connector. One Year Warranty. The NI SCXI-1362 is compatible with several SCXI switch modules. 68M-50F STEP User Manual. 0. com Conventions The following conventions are used in this guide: » The » symbol leads you through nested menu items and dialog box options to a final action. If your switch module cannot connect to the SCXI-1357 then you can use the SCXI-1362 Adapter Kit to connect to your DMM. SCXI-1125 SCXI-1304/5 Ð BNC connectors, AC/DC coupling and ground referencing SCXI-1313A 3 Extends signal input range to 150 Vrms,programmable per channel SCXI-1320 3 Ð SCXI-1327 3 Extends signal input range to 300 Vrms,switch configurable per channel SCXI-1328 3 Isothermal, high-accuracy design for thermocouplesCatalog Datasheet MFG & Type PDF Document Tags; PCI-8335. 1362 Hastings St , Victoria, BC V8Z2W is currently not for sale. Position the NI PXI chassis so that inlet and. Part Numbers: 185258-01, 185258B-01 National Instruments PXI-4021 Switch ControllerPart Number: 184793G-02, 184793E-02 This enables the SCXI system to be located closer to the sensors and transducers. The SCXI-1192 general-purpose 18 GHz module can handle RF signals to a maximum of 18 GHz. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Downloadable Technical Manuals and Datasheets. controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. Fast Quotes & Shipping. 1553. com. Buy, Sell, Repair, or Calibrate National Instruments SCXI Modules. 185436A-01 National Instruments 185436A-01 8-Position High Voltage Analog Bus (HVAB) Backplane Adapter from National Instruments | Buy Today from Artisan. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. can communicate with all SCXI modules containing a 10-pin rear connector,while the SCXI-1362 provides connectivity to all modules containing a 50-pin rear connector. 3 GHz. The maximum rated voltage of the module is 30 V, whereas the maximum rated current. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. Find. SCXI-1357, SCXI-1358 High-Voltage Backplane Assemblies High-voltage backplane assemblies for the SCXI-1127, SCXI-1128 and SCXI-1129 multiplexer/matrix modules. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. Abstract: SH1006868 SH6868-EP 776291-91 PSHR68-68 CA-1000 FOR5B 776236-01 Text: channels and digital I/O lines using a standard SH6868-EP or. SCXI Backplane Adapter Connector. com Channel Signals Table 1 lists the signal names of the terminals for each channel, and listsThe SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. SCXI-1346 Multichassis Adapter Computer with E Series board SCXI Chassis SH6868-EP cables SCXI-1349 or SCXI-1353 adapter SH6868-EP or SH1006868 cable SCXI-1346 multichassis adapter Figure 10. Most current M series cards are only shipped with hybrid Connector and cannot be used to control the SCXI portion of a PXI/SCXI Combination Chassis. Add to Cart. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI. National Instruments SCXI-1346 Multi-Chassis Cable Adapter. National Instruments SCXI-1160 : National Instruments SCXI-1160 -- Related Product Links:. com or CALL 800 813 3693 (U. The highest rated voltage is 24 V, while the highest rated current is 1 A at 24 V. National Instruments 181625-01 Rear Filler Panel for SCXI-1361. This cable is included in the SCXI-1357SCXI-1166 SCXI-1366 Screw terminal for 32 relays 777687-66 Backshell connector kit for custom cable (requires two) 778720-01. Fax: (240) 376-1381. controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. 13 pages. SCXI-1358, SCXI-1359, and SCXI-1362. With the SCXI-1362 adapter kit, you can connect the NI 4021 or NI 4060 to the following switch modules: SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, SCXI-1191, or SCXI-1192. lang:en score:40 filesize: 2. 描述: 776575-62 是 有 National Instruments 776575-62 SCXI-1362 LOW 电压 背板 生产厂家: National Instruments National Instruments - NI提供功能强大,灵活的技术解决方案,可提高生产力并推动快速创新。 从日常任务到重大挑战,NI帮助工程师. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 1362 Dallas Road has some transit which means a few nearby public transportation options. This warranty includes parts and labor. Adapter National Instruments SCXI 1346 Installation Manual. SCXI Backplane Adapter Connector. Particle Sizers / CountersGet a quote for a Used PCI 4021 Miscellaneous Controllers from Apex Waves, LLC at used-line. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. With the SCXI-1362 adapter kit, you can connect the NI 4021 or NI 4060 to the following switch modules: SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, SCXI-1191, or SCXI-1192. Recorders / DataloggersSite Search Results. 1 Shunt Resistor Sockets 1. SCXI-1349 SCXI-1349 68-pin SH68-68-EP 50-pin SCXI-1000DC SCXI-1382 184749-02 SCXI-1180 PCI-DIO-32hs SCXI-1001 PXI-4070 PXI-6534 SCXI 1163 CB-50 SH96-6868: SH68-68-EP. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. With a front-panel trimming potentiometer, you can manually. are not included with this equipment unless listed in the above stock item description. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Fax: (240) 376-1381. PRT STP IGS Product Support Resources. Shielded multi-chassis cable adapter (19 pages). From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Solution. arinccontroller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI. This icon denotes a note, which alerts. Ships in 5-10 Days. Connect one end of the SH9MD-AUX cable to the NI SCXI-1362 cable adapter and the other end to the NI 4021/4060/407x. These modules are integrated inside an SCXI chassis. This is used with the SCXI Low Voltage Adapter board, SCXI-1362. This enables the SCXI system to be located closer to the sensors and transducers. SCXI-1358, SCXI-1359, and SCXI-1362. The SCXI-1362 works much like the SCXI-1357 in that it uses the AUX I/O port to communicate digitally with the DMM. Adapter kit (7 pages) Adapter National Instruments NI 5782R User Manual And Specifications. Page 9: About This Manual. View cart. SCXI Terminal Blocks 3 BUY ONLINE at ni. National Instruments SCXI-1341 Adapter BoardThis unit has a broken connector. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The NI SCXI-1190 can be controlled in an application development environment with the use of NI-SWITCH. controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. This cable is included in the SCXI-1357National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThis unit is sealed in the manufacturer's bag. To connect the signal to the terminal block, perform the following steps, referring to Figures 1 and 2 as necessary: 1. SCXI-1349 SCXI-1349 68-pin SH68-68-EP 50-pin SCXI-1000DC SCXI-1382 184749-02 SCXI-1180 PCI-DIO-32hs SCXI-1001 PXI-4070 PXI-6534 SCXI 1163 CB-50 SH96-6868: SH68-68-EP. The SCXI-1190 is a Quad 4-Channel Multiplexing Switch Module. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01The SCXI-1304 AC/DC is a shielded terminal block with screw terminals that you can connect to the SCXI-1140, SCXI-1141/1142/1143, SCXI-1120/D, SCXI-1125, or SCXI-1126 input connector. SCXI Backplane Adapter Connector. Both the NI 1359 and SCXI-1362 provide options for connecting to a DMM such as an NI 407x or an NI 4021From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Trusted Supplier for Industrial & Military. The cable SCXI module can be an SCXI signal conditioning. 본 페이지는 scxi-1362 의 치수도면을 제공합니다. • SCXI Chassis User Manual—If you are using SCXI, read this manual for maintenance information on the chassis and for installation instructions. Part Number: 181765-01 View Photo of broken connector. Page 1 SCXI-1194. The SCXI-1346 (Part Number: 776574-46) is meant for applications involving multi-chassis SCXI because it can join them to one DAQ device. Manuals. pdf file (06 Sep 2023) Manufacturer: Sandel Category of Device: Adapter, GPS Document: SG102 Operation & User’s Manual, File Type: PDF Updated: 06-09-2023 Count of Pages: 22 Download SG102 Manual (22 pages)SCXI-1126 SCXI-1327 Extends signal input range to 250 V rms, switch configurable per channel SCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1338 Current Input, 249 resistor across each input SCXI-1125 SCXI-1304/5 – BNC connectors, AC/DC coupling and ground referencing SCXI-1313 Extends signal input range to 300 VNI SCXI-1331 Installation Instructions 8 ni. National Instruments PXI-4021 Switch ControllerPart Number: 184793G-02, 778277-01SCXI Backplane Adapter Connector. SCXI-1163R. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module. With the SCXI-1362 adapter kit, you can. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Adapter National Instruments SCXI-1362 Installation Manual. ni scxiスイッチモジュールにはni-switch 計測器ドライバ が同梱されており、このドライバはデバイスのプログラミングに使用します。 このドキュメントには、NI スイッチモジュールのプログラミングにも使用できるNI-The SCXI-1362 is a National Instruments Adapter Board with a Features Multiple SCXI Cables / Adapters . 1. Trusted Supplier for Industrial & Military. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. To connect the signal to the terminal block, perform the following steps, referring to Figures 1 and 2 as necessary: 1. 2. It interfaces to field digital logic signals, such as. SCXI-1358, SCXI-1359, and SCXI-1362. Connecting the SCXI-1348 to the SC-2057 and SCXI Module. 3. Power off both the PXI and SCXI power switches, and unplug the chassis. SCXI-1358, SCXI-1359, and SCXI-1362. Bus lines: 3 Beacon Hill / Gonzales. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. 2D Dimensional Drawings. PRT STP IGS Product Support Resources. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. In most applications, this is the most convenient grounding option. NI SCXI-1600 when used with. • SCXI Chassis User Manual—If you are using SCXI, read this manual for maintenance information on the chassis and for installation instructions. 2. arinc & 1553 . We offer repair services with a 1 week turnaround and calibration services with a 2 week turnaround. This document explains how to install, configure, and set up a National Instruments SCXI switch module. 3. User Manual Guide SCXI 1161 User Manual 320514B 01 May 1997 Technical Publications National Instruments Network Card Guide ec461d63 1d6e 40e5. 00mm (0. All prices are shown in USD. . With the NI 4021 kit, you can control an SCXI module via a high-voltageSite Search Results. 1. Figure 1. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. With the NI 4021 kit, you can control an SCXI module via a high-voltageSCXI-1358 kit or SCXI-1359 kit SCXI-1357 kit or SCXI-1358 kit or SCXI-1359 kit USB-1357 kit or USB-1358 kit or USB-1359 kit Indirect control† SCXI-1128 SCXI-1129 SCXI-1130 Not supported* All other modules SCXI-1160‡ SCXI-1362 kit SCXI-1362 kit SCXI-1362 kit Indirect control** SH6868-EP and SCXI-1349 SCXI-1161‡ SCXI-1163R SCXI-1190National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThe 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. Abstract: PXI-PCI8330 PXI-8330 PCI-8330 MXI-3 8335 MXI3 10 8335 PXI-833x 8330 Series Text: Embedded and Remote Controllers PXI-PCI8330 Series, PCI-8330 Series, PXI-8330 Series MXI-3 , , using the new MXI-3 technology. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. S. This module has 8 SPDT relays with 2 channels per relay and is not supportive of routing signals to the high-voltage analog bus. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. 7 pages. 1-slot adapters are sold separately. PRT STP IGS Product Support Resources. arincan 1358 datasheet, cross reference, circuit and application notes in pdf format. You can configure each SCXI-1304 channel to provide AC or DC coupling of a signal to the SCXI module, and each channel can ground reference aSCXI-1161 Switch Module LabVIEW, SCXI-1161, Switch Module LabVIEW, Module LabVIEW, LabVIEW: User Manual: 2023-05-16: Documents - national instruments – scxi 1161,scxi-1161 . This document contains information about the NI-DAQmx driver software, which you canarinc & 1553 . Adapter kit (7 pages) Adapter National Instruments SCXI 1346 Installation Manual. Since this Switch Module’s relays can switch at a maximum of 8 A at 125 Vrms, 6 A at 250 Vrms, or 5. The SCXI-1160 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Show More Description. Contact us. National Instruments PXI-4021 Switch ControllerPart Number: 184793G-02, 778277-01 SCXI Backplane Adapter Connector. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. The 4 bed, 3 bath house for sale at 3825 Synod Rd, Saanich is. arinc & 1553 . Part Number: 181765-01 View Photo of broken connector. 2. com Alternatively, you can use the following formulas: T(°C) = T K – 273. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Note When connecting your signals to the SCXI-1327, follow the labeling on the SCXI-1327 for the appropriate module, as indicated in Figure 2. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Page 21: Using Jumpers W4 And W5The SCXI-1102, SCXI-1102B, and SCXI-1102C modules are warranted against defects in materials and workmanship for a period of on e year from the date of shipment, as evidenced by receipts or other documentation. SCXI Backplane Adapter Connector. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connectSCXI-1166 SCXI-1366 Screw terminal for 32 relays 777687-66 Backshell connector kit for custom cable (requires two) 778720-01. Multichassis SCXI System with Shielded Cabling AssembliesSCXI-1362 Cable Assembly Figure 8. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 11 pages. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI. SCXI-1127, SCXI-1128, or SCXI-1129 module users, should refer to the SCXI-1357 or SCXI-1358 high-voltage analog bus. Experienced Expert Engineers that. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. Loosen the strain-relief screws and remove the strain-relief bar. . 5 9-Pin (DB9) Deluxe D-Sub Cable - Copper Shielded - Male / Female 2. It ships as photoed. 5. Our connector part numbers list for part type Signal Conditioning Equipment indexes items by part numbers such as NI-SCXI-1128-High-Voltage-FET-Multiplexer Matrix-Switch,. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. NI SCXI Chassis. SCXI Backplane Adapter Connector. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. 1180, 776572, SCXI-1353, 776575, SCXI-1355, SCXI-1356, SCXI-1358, SCXI-1343, SCXI-1351, SCXI-1362, SCXI-1181,. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI. 1. The SCXI-1302 has a 50-screw terminal block for SCXI-1180 feedthrough panel or SCXI-1200 Module. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI. National Instruments SCXI-1160 products for sale at Test Equipment Center are thoroughly tested, and receive electrical and cosmetic. It is practical to mix SCXI and PXI. PDF DXF 3D CAD Models. SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. National Instruments SCXI-1359 2-Slot High Voltage Backplane Adaptor. User Manual And Specifications. SCXI-1127, SCXI-1331 (Figure 6) Multiplexer 777687-31 SCXI-1128 SCXI-1332 Matrix 777687-32 Matrix expansion Use with the SCXI-1332 to connect the rows 0. 40 m 185440-0R4 cables (Figure 7) and columns of adjacent terminal blocks. 3. 12 pages. Find National Instruments, Universal Instruments, Agilent - Keysight, and Ingersoll Rand for sale on Machinio. National Instruments SCXI-1129 with electromechanical relays. Fast Quotes & Shipping. SCXI-1127, SCXI-1128, or SCXI-1129 module users, should refer to the SCXI-1357 or SCXI-1358 high-voltage analog bus. Part Number: 182363D-01, 185136B-01, 185136A-01. Whether you need to measure sensors or raw signals, generate voltages or currents, monitor digital lines, or route signals with switching, SCXI provides a single, integrated. Signal Conditioning Equipment Electrical connectors and parts such as SCXI-1163R, NI-TBX-24F, NI-SCXI-1194-2 5-GHz-50-Quad-4x1-Mux-Insertion-Loss-1 35-d, NI-SCXI-1175-196-Channel-Multiplexer-Switch-Module, NI-SCXI-1167-64-Channel-External-Relay-Driver-Module available for instant free quote. Figure 2. Part Number:The NI SCXI-1163 (Part Number: 776572-63) is an isolated Digital Output Module. SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI. 0. SCXI Backplane Adapter Connector. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The TC-2095 adapter has 32 uncompensated . SCXI Backplane Adapter Connector—The SCXI-1362 Kit includes an SCXI-1362 backplane and an SH9MD-AUX cable. Signal Conditioning Equipment Electrical connectors and parts such as SCXI-1163R, NI-TBX-24F, NI-SCXI-1194-2 5-GHz-50-Quad-4x1-Mux-Insertion-Loss-1 35-d, NI-SCXI-1175-196-Channel-Multiplexer-Switch-Module, NI-SCXI-1167-64-Channel-External-Relay-Driver-Module available for instant free quote. 2. lang:en score:57 filesize: 1. ft. National Instruments SCXI-1362 Low Voltage Adapter Board Part Number:. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. They consist of high-quality,low-noise cables,which guarantee reliable communication and signal integrity at up to 10 m. National Instruments 185436A-01 8-Position High Voltage Analog Bus (HVAB) Backplane Adapter | Easy Click-Quote-Buy Today! Fast Shipping. The SCXI-1362. Texas Instruments AC ''97 Rev 2. The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. To use a mixed system for Signal Conditioning the user can either purchase a mixed SCXI/PXI single source chassis from NI or use two different chassis, typically controlled from an. The terminal block has 48 screw terminals for easy signal connections. These accessories are the ideal. The switch modules that can be used with the SCXI-1362 are: SCXI-1160; SCXI-1161; SCXI-1163R Phone: (217) 352-9330. Catalog Datasheet MFG & Type PDF Document Tags; PCI-8335. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. OtherSwitch National Instruments NI 2565 User Manual. 2. During multichassis expansion the SH9MD-AUX cable is used to connect two SCXI-1362 backplanes. Existing Controller. SCXI Backplane Adapter Connector. SCXI-1351 One-Slot Cable Extender Figure 7. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. This page provides dimensional drawings for the SCXI-1362. Fast Quotes & Shipping. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help.